NEWS



17

2022

-

10

Process requirements for communication towers

Author:


1) The design and construction of communication towers should be closely coordinated with the communication process to meet its requirements. While determining the height of the mast, the number of platforms, the specifications, quantity, and direction of the antenna, and the direction of the feeder, the possibility and convenience of expansion should be fully considered.

(2) The steel tower should be set up at the height of the hanging antenna maintenance platform, the platform width should consider the spacing requirements of the antenna, and the net width should not be less than 600mm, and the platform should be set to a railing with a height of 1.1m; The fence needs to be firm and reliable, and the fence is made of angle steel of 50mmX50mmX5mm or more, and the angle steel is firmly connected to each other. When the height of the mast is greater than 50 meters, it is advisable to add a rest platform in the middle.

(3) The antenna bracket should not extend beyond the platform edge of more than 800mm, and the antenna bracket should be designed as a retractable and active type when it exceeds 800mm.